Introducing the KSTAR KS-UA200 2,000VA Line Interactive UPS, a robust and intelligent power protection solution designed to keep your critical equipment safe from power disturbances. With advanced features such as AVR boost and buck, cold start function, smart RS-232/USB interface for power management, built-in self-diagnostic function, modem/LAN internet protection, and optional generator compatibility, this UPS ensures uninterrupted power supply and optimal performance for your valuable devices.
The Automatic Voltage Regulation (AVR) feature of the KSTAR KS-UA200 UPS is a crucial component in maintaining a stable output voltage. It automatically corrects overvoltage and undervoltage conditions, providing a consistent and optimal voltage level to the connected devices. This helps safeguard sensitive equipment from potential damage caused by voltage fluctuations and ensures reliable operation.
The cold start function is a valuable feature that allows the KS-UA200 UPS to power up even in the absence of utility power. In situations where the power supply is completely disrupted, this UPS can start running on its internal battery, ensuring continued operation of your critical systems until the main power is restored. This capability provides an additional layer of reliability and protection.
For efficient power management and monitoring, the KS-UA200 UPS comes equipped with a smart RS-232/USB interface. This interface allows you to connect the UPS to your computer or network, enabling real-time monitoring of power status, battery health, and other essential parameters. It also facilitates automatic shutdown of the connected devices during extended power outages, safeguarding data integrity and system stability.
The built-in self-diagnostic function of the KS-UA200 UPS is a proactive feature that continuously monitors the UPS’s internal components and battery health. It performs periodic self-tests to detect any potential issues and promptly alerts you in case of abnormalities. This proactive approach enhances the reliability and performance of the UPS, providing you with peace of mind and minimizing downtime.
In today’s interconnected world, protecting your network equipment and data is paramount. The KS-UA200 UPS offers modem/LAN internet protection, safeguarding your network devices from power surges and fluctuations. This ensures uninterrupted internet connectivity and protects valuable data and communications.
For users relying on backup power from generators, the KS-UA200 UPS is generator compatible (optional). It can seamlessly integrate with a generator power supply, providing an uninterrupted power source and extending the runtime during extended outages.
In conclusion, the KSTAR KS-UA200 2,000VA Line Interactive UPS is a feature-rich power protection solution designed to provide reliable and efficient power backup for your critical devices. With AVR boost and buck, cold start function, smart interface, self-diagnostic capability, modem/LAN internet protection, and optional generator compatibility, this UPS offers comprehensive power protection and ensures your valuable equipment remains operational, connected, and secure during power disturbances. Rely on KSTAR’s reputation for quality and innovation and equip your critical systems with the KS-UA200 UPS for dependable power protection. View All Products
Weight | 11.5 kg |
---|---|
Dimensions | 38 × 15.8 × 19.8 cm |
Specification
In conclusion, the KSTAR KS-UA200 2,000VA Line Interactive UPS is a feature-rich power protection solution designed to provide reliable and efficient power backup for your critical devices. With AVR boost and buck, cold start function, smart interface, self-diagnostic capability, modem/LAN internet protection, and optional generator compatibility, this UPS offers comprehensive power protection and ensures your valuable equipment remains operational, connected, and secure during power disturbances. Rely on KSTAR’s reputation for quality and innovation and equip your critical systems with the KS-UA200 UPS for dependable power protection.
Model
|
UA40 | UA60 | UA80 | UA100 | UA120 | UA150 | UA200 | UA240 | UA300 |
Capacity
(VA/Watts) |
400 / 240 | 600/ 360 | 800 /480 | 1000/ 600 | 1200/ 720 | 1500 / 900 | 2000 / 1200 | 2400/ 1440 | 3000 / 1800 |
INPUT
|
|||||||||
Nominal Input
Voltage |
110/120Vac or 220/230/240 Vac | ||||||||
Operating
Voltage Range |
81-145Vac/162-290 Vac | ||||||||
Operating
FrequencyRange |
50/60 Hz (1±10%) | ||||||||
OUTPUT
|
|||||||||
Output Voltage
range (Batt. Mode) |
Simulated Sinewave at nominal voltage ±10% | ||||||||
Frequency Range
(Batt. Mode) |
50 Hz or 60 Hz ± 1 Hz | ||||||||
Transfer Time
|
Typical 2-6 ms, 10ms max. | ||||||||
BATTERY
|
|||||||||
Battery Type
& Number |
12V/4.5Ah x 1 | 12V/7Ah x 1 | 12V/9Ah x 1 | 12V/7Ah x 2 | 12V/7Ah x2 | 12V/9Ah x 2 | 12V/9Ah x 2 | 12V/7Ah x 4 | 12V/9Ah x 4 |
Typical Recharge
Time |
6-8 hours ( To 90% capacity) | ||||||||
PROTECTION
|
|||||||||
Full Protection
|
Overload and overcharge protection | ||||||||
INDICATORS
|
|||||||||
Indicators
|
AC Mode, Battery Mode, Load Level, Battery Level | AC Mode, Battery Mode, Load Level, Battery Level, Input Voltage, Output Voltage, Overload, Fault, Battery Low |
|||||||
ALARM
|
|||||||||
Battery Mode
|
Sounding every 10 seconds | ||||||||
Battery Low
|
Sounding every second | ||||||||
Overload
|
Sounding every 0.5 second | ||||||||
Battery
Replacement Alarm |
Sounding every 2 seconds | ||||||||
Fault
|
Continuously sounding | ||||||||
Management
|
|||||||||
USB & RS-232
port(Optional) |
Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7, Linux, Unix, and MAC | ||||||||
Environment
|
|||||||||
Operating
Temperature |
0- 40°C | ||||||||
Humidity Range
|
0-95 % (Non-condensing) | ||||||||
Noise Level
|
<40db (1 meter from surface) | ||||||||
PHYSICAL
|
|||||||||
Dimension,
W x D x H (mm) |
101×298×142 | 149.3×338×162 | 158×380×198 | 144×432.5×207 | |||||
Net Weight (kg)
|
3.55 | 4.25 | 4.9 | 7.8 | 8 | 11.1 | 11.5 | 20 | 23 |
STANDARDS
|
|||||||||
Safety
|
IEC/EN62040-1;IEC/EN60950-1 | ||||||||
EMC
|
IEC/EN62040-2;IEC61000-4-2;IEC61000-4-3;IEC61000-4-4;IEC61000-4-5;IEC61000-4-6;IEC61000-4-8 |
Only logged in customers who have purchased this product may leave a review.
Reviews
There are no reviews yet.